Manx SA7x Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Elektrické skříně Manx SA7x. Manx SA7x Installation guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Upgrade Installation Guide

SA7x/6000 Cabinet SeriesUpgrade Installation GuideOrder Number EK–SA7CK–IN–003Digital Equipment CorporationMaynard, Massachusetts

Strany 2

1.2 SA70–CK Parts ListThe SA70–CK kit contents are listed in Table 1–2. Be sure all contents of the kit are presentbefore starting the installation pr

Strany 3 - Contents

Table 1–2 (Cont.): SA70–CK Kit Parts ListPart Number Description Quantity90–08264–00 Cable mount 190–07087–00 5/8-inch cable clamp 290–00063–41 10–32

Strany 4

1.3 Unpacking the SA70–LK/MK, SA71–NK/PK, SA72–NK/PK, andSA73–NK/PK OptionsThe SA7x options are shipped in a packaging box. The SA70–CK kit are shippe

Strany 5

Figure 1–1: Unpacking the SA70 EnclosureCONTAINERDESICCANTSHIPPINGSTRAPSCXO-2439B_SMANUALS ANDMOUNTINGHARDWARESA7xENCLOSURE1–6 SA70–CK and Upgrade Kit

Strany 6 - Document Structure

Chapter 2Safety Precautions2.1 IntroductionThis chapter discusses hazards and safety precautions that the Digital Services engineershould be aware of

Strany 7

Chapter 3Installing the SA70–CK Kit3.1 IntroductionThis chapter describes the following:• How to power down the VAX 6000-series processor cabinet• How

Strany 8 - SA70–CK and Upgrade Kits

Figure 3–1: Front View of the VAX 6000-Series Processor CabinetCXO-2787AFRONT DOORKEY PINFRONT DOORKEY PINGROUNDSTRAPOCP ACCESSPANEL3–2 Installing the

Strany 9

Figure 3–2: Rear View of the VAX 6000-Series Processor CabinetCXO-2788AESDPACKETH405 POWERCONTROLLERPOWERCONTROLLERSCREWS (6)ESDGROUNDLUGInstalling th

Strany 10 - 1.2 SA70–CK Parts List

3.2 Powering Down the CabinetThe VAX 6000-series processor cabinets use H405 power controllers. To remove power fromthe cabinet, use the following pro

Strany 11 - 1–4 SA70–CK and Upgrade Kits

Figure 3–3: Cabinet Control Panel and Power ControllerStandbyEnableSecureAuto StartBatteryRestartRunFaultUpdateHaltONOFF0CONTROL PANELH405-E OR -FPOWE

Strany 12 - SA73–NK/PK Options

First Revision, October 1989Second Revision, April 1992Third Revision, September 1992The information in this document is subject to change without not

Strany 13 - 1–6 SA70–CK and Upgrade Kits

If the H405–E/F revision level is:a. Revision H07 or above for H405–E, Revision J07 or above for H405–F:• The H405–E/F power controller contains unswi

Strany 14 - Safety Precautions

4. Swing the top of the door away from the cabinet, lift the bottom of the door up and outof the bottom hinge, and set the door aside.To install the n

Strany 15 - Chapter 3

3.6.2 Moving the ESD StrapUse the following procedure to move and reattach the ESD strap:1. Locate the front ESD packet, shown in Figure 3–4. The pack

Strany 16

3.6.3 Installing the 74-39405-01 BeCu Spring ClipsUse the following procedure to install beryllium copper (BeCu) spring clips:1. Install one BeCu spri

Strany 17

Figure 3–5: Installing BeCu Spring ClipsSPRINGCLIPSLOCATIONSPRINGCLIPSLOCATIONCABINETUPRIGHTCABINETBASESPRINGCLIPS.50CXO-2795A.50CABINETCENTERDIVIDER.

Strany 18 - 3.2 Powering Down the Cabinet

5. Go to the front of the cabinet. Install washer (90–06637–00) and shoulder screw (12–24007–02) into the front center hole of the guide rail plate as

Strany 19

Figure 3–6: Installing the Guide Rail Plate AssemblySCREW12-24007-02WASHER90-06637-00GUIDE RAILPLATE ASSEMBLYBOTTOMREARSTANDOFFWASHER (3)90-06637-00SC

Strany 20

Figure 3–7: Chassis Retainer Brackets and Shim OrientationGUIDE RAILPLATE ASSEMBLYSCREW12-24007-01SCREW12-24007-01WASHER90-06637-00WASHER90-06637-00TO

Strany 21

12. Install the washer (90–06637–00) and shoulder screw (12–24007–01) through the bottomhole of the chassis retaining bracket and into the middle hole

Strany 22 - 3.6.2 Moving the ESD Strap

Figure 3–8: Front Clamping AssemblyTOPCHASSISRETAININGBRACKETBOTTOMCHASSISRETAININGBRACKETCXO-2794BTOPSHIMRAIL CHASSISASSEMBLYGUIDERAILASSEMBLYCABINET

Strany 23

ContentsPreface viiChapter 1 SA70–CK and Upgrade Kits1.1 Introduction . ...1–11.2 SA70–CK Parts

Strany 24

3. Lift and move the SA7x enclosure into place using a Digital lifting device (FC–10117–AC).WARNINGIf a lifting device is not available, two people ar

Strany 25

Figure 3–9: Rear Clamping AssemblySA7xENCLOSURECHASSISHOLE 2 OFMOUNTINGSPACERAILCHASSISASSEMBLYCXO-2807B_SCABINETREARVERTICALUPRIGHTREAR RETAINERCHASS

Strany 26

Figure 3–10: Installing the Digital MedallionFRONTCOVERUnit SelectRunRunFault/Fault/Set No.Set No.Ready ReadyUnit No.Unit No.Write WriteProtect Protec

Strany 27

Figure 3–11: Repositioning Transition Board 1CXO-2797ATRANSITIONBOARD 1(BEHIND FRAME)SLOTTEDHOLESLOTTEDHOLEHOLE FORTB1 RIGHTPOSITIONHOLE FORTB1 LEFTPO

Strany 28

2. Route the SA7x enclosure power cord through the clamp attached to the cable manage-ment guide as shown in Figure 3–12.3. Plug the male end of the S

Strany 29

Figure 3–12: Attaching a Single SDI Cable to the SA7x and KDB50/KDM70 I/O BulkheadLRLFRFRRRFGREYSHORTLRYELLOWLONGRRBLACKLONGLFREDSHORTPORT A I/O CABLE

Strany 30

Figure 3–13: Attaching a Second SDI Cable to the SA7x and KDB50/KDM70 I/O BulkheadLRLRLFLFRFRFRRRRRFGREYSHORTLRYELLOWLONGRRBLACKLONGLFREDSHORTPORT A I

Strany 31

Figure 3–14: Cabinet Control Panel and Power ControllerStandbyEnableSecureAuto StartBatteryRestartRunFaultUpdateHaltONOFF0CONTROL PANELH405-E OR -FPOW

Strany 32 - CXO-2796A

Chapter 4SA7x Controls and IndicatorsThis chapter describes the controls and indicators on the front and rear panels of the SA7xenclosure.4.1 SA7x Fro

Strany 33

Figure 4–1: Front Panel View of the SA7x EnclosureFRONTCOVERLEFTFRONTLEFTREARRIGHTREARRIGHTFRONTDRIVE POWER SWITCHESCXO-2447A_SRIGHTREARRIGHTFRONTLEFT

Strany 34 - 3.8 Powering Up the Cabinet

3.7.2 Installing the Rear Clamping Assembly ...3–163.7.3 Installing the Digital Medallion ...

Strany 35

While a drive is powering up and spinning up, the controls and indicators have slightlymodified meanings, as described in Section 5.2.Each control set

Strany 36

Table 4–1 (Cont.): Front Panel Controls and IndicatorsPressing this Switch Performs this Function Illuminates this IndicatorRun switch Spins up the dr

Strany 37

4.2 SA7x Rear Panel Controls and IndicatorsAll rear panel controls and indicators are located on the power supply chassis, as shown inFigure 4–2.Figur

Strany 38 - SA7x Controls and Indicators

4.2.1 Master On/Off SwitchThe master on/off rocker switch for the SA7x enclosure is located in the center of the rearpanel. Setting the switch to 1 ap

Strany 39

Chapter 5Powering Up the SA7x EnclosureThis chapter explains how to use the SA7x enclosure and drives and how to set the unitnumber.5.1 Powering Up th

Strany 40

The disk drive starts the drive’s internal power-on diagnostics. All indicator lightsilluminate for about 8 seconds. Then:a. If the drive completes th

Strany 41

5.4 Setting the Unit NumberThe unit number for any drive can be set at the operator control panel. This is the numberby which the drive is known to th

Strany 42 - Figure 4–2

Chapter 6Installing RA7x Disk DrivesThis chapter describes how to install additional RA7x disk drives into SA7x enclosures thatare not fully populated

Strany 43 - 4.2.1 Master On/Off Switch

2. Set the master on/off switch to 0. This removes power to the enclosure.6.3 Installing the RA7x Disk DriveTo install additional drives, remove the f

Strany 44 - Chapter 5

Figure 6–1: Installing Add-On RA7x Disk DrivesSHOE PLATERETAINING CLIPSHOE PLATERA7x DISK DRIVEREAR PANELSHOE PLATEGUIDEINTERNALSDI CABLESCXO-3442A_SL

Strany 45 - 5.3 Placing a Drive Off Line

3–11 Repositioning Transition Board 1 ...3–193–12 Attaching a Single SDI Cable to the SA7x and KDB50/KDM70 I/O Bulkhea

Strany 46 - 5.4 Setting the Unit Number

Index70–27273–01See SA70–CKAAdd-on kitSee SA7x enclosure add-on kitAir flow, 5–1BBeCu spring clipsinstalling, 3–9Beryllium copper spring clipsSee BeCu

Strany 47 - Installing RA7x Disk Drives

Indicators (cont’d)functions, 4–4, 4–5rear panel, 4–5types, 4–1, 4–4KKDB50/KDM70 disk controller I/O bulkhead, 3–20LLine voltage select switch, 4–4, 4

Strany 48

VAX 6000-series processor cabinet (cont’d)safety precautions, 2–1, 3–1Voltage select switchSee Line voltage select switchWWrite Protect indicator, 4–4

Strany 49

PrefaceThis manual describes:• How to unpack the SA70–LK/MK, SA71–NK/PK, SA72–NK/PK, or the SA73–NK/PKoptions.• Safety precautions for Digital Service

Strany 50

ScopeGeneral information about the VAX 6000-series processor cabinet and field acceptanceprocedures is not contained in this manual. Refer to documenta

Strany 51

Chapter 1SA70–CK and Upgrade Kits1.1 IntroductionThis chapter a brief description and parts list of the SA7x options and related upgradekits available

Strany 52

Table 1–1 (Cont.): SA7x Options for VAX 6000 Embedded StorageOption DescriptionSA72-PK SA72-JK Storage Enclosure with 4 GB (4 RA72) Disk Storage capac

Komentáře k této Příručce